Recorders Pane
The following elements can be displayed in the Recorders pane:
Enabled
This column indicates whether or not the recorder is activated.
When the recorder is activated, the
symbol is displayed. If not, the
symbol is
displayed.
If the
symbol is displayed, the recorder is
configured incompletely or incorrectly.
Name
This column displays the name of the recorder. The default recorder is also marked by a * symbol and cannot be deleted.
Status
The status is indicated in this field. The following statuses are possible:
- Inactive
- Waiting for trigger
- Record
- Wait for comment
Reliable Trigger
This column displays the delay if the data volume is too large to be permanently buffered (Define Automatic Start Trigger, Define Automatic Stop Trigger).
Recordings
This column displays the number of records. The sum total comprises the initial record and the number of repeats set in the recorder configuration.
Note |
This option is available only for trigger-controlled records. |
Trigger PreStart
This column displays the prestart time set in the recorder configuration.
Note |
This option is available only for trigger-controlled records. |
Duration
This column indicates how long each recorder has been recording.
Remaining Time
This column indicates how long a started recorder still has to run.
Note |
Requirement: a fixed recording time has been set in the recorder configuration. |
Post Stop
This column displays the run-on time set in the trigger definition.
Note |
This option is available only for trigger-controlled records. |
Timestamp Errors
This column displays the number of errors determined by the plausibility check (Settings for checking the plausibility of timestamps).
See also
Recorder Manager Preferences Dialog Box
Settings for checking the plausibility of time stamps
You can