Setting up a Cyclic or Random Stimulation Mode
To set up a or random generator stimulation mode, proceed as follows:
- Open the Stimulus window for a data generator channel (Setting up a Channel in the Data Generator).
In the Mode combo box, select a cyclic or random mode.
Available cyclic modes: sine, ramp, pulse, step, random
- In the Frequency field, set the frequency in Hz (i.e. 1/s, not rad/s) for the cyclic mode.
In the Phase field, set the phase for the cyclic mode.
The phase determines the offset from the time axis. If, e.g. the phase of a sine signal is 0.5 seconds, the signal will be shifted to the right by half a second.
Note
The Frequency and Phase fields are not available for the random mode.
- Set the offset of the y-axis (Offset field).
- Adjust the amplitude.
- Click OK or Apply.
See also
Example: Sinus Stimulation Mode