Programming the ETK Flash

To program the contents of the ETK flash EPROM:

  1. In the Devices field, select the devices for which you want to perform the selected action.
  2. In the Action field, activate Flash programming.
  3. Check the Calibration access box.
  4. In the Apply to field, activate the corresponding setting:

    • Data to program the datasets
    • Code + Data to program the datasets and the code page
  5. Highlight the source in the From field:

    • Working page (+ Code page) to program the working dataset (and the code page if you select Code + Data)
    • Reference page (+ Code page) to program the reference dataset (and the code page if you select Code + Data)
  6. In the To field, highlight ETK flash.
  7. If necessary, activate or deactivate the control device group in the Device group active field.
  8. Check the settings from the visual display of the selected action:

    The source is underlaid blue, the destination is underlaid orange.

  9. Click Do It.

    The ETK flash EPROM is programmed. The flash programming progress is displayed via dialog message boxes.

  10. To determine the reinitialization behavior after a flash process is completed, select one of the options of the Confirm - Reinitialization Dialog Box dialog box.

See also

Reading from ETK Flash

Programming the ECU Flash

Confirm - Reinitialization Dialog Box