Module Parameter for SOME/IP Monitoring
The following shows the module parameters for SOME/IP monitoring:
Enter any name for the hardware module.
Specifies how the system should react if the connection between INCA and the hardware module is interrupted at measuring start or during measurement.
Abort after failure
The measurement using this hardware module will be terminated in any case of measurement failure (at measuring start or during measurement). The system does not try to reinitialize the hardware module. After the connection has been interrupted, you have to reinitialize manually.
This option is appropriate when, e.g., the measured values are not essential for the experiment, as the module will be ignored after any failure. This option is the default.
Abort at start, try again later
INCA stops measurement of this module in case of failure at measuring start, assuming the module is disconnected or has any systematic problem.
It continues to try measurement in case of failure during the measurement assuming the failure is temporal and can be resolved via retries.
Retry always
INCA continues to try measurement of this module in any case of measurement failure (at measuring start or during measurement).
This option is useful if you want to conduct quick start or cold start measurements.
Shows the name of the PDU cluster of the AUTOSAR file.
To select a different project: in the Value column, double-click the field next to Project.
Defines if INCA checks or ignores the specified MAC addresses.
Ignored | Packets pass the packet capture filter even if the property does not match. This is the default value. |
Checked | Packets are checked and filtered. INCA uses the AUTOSAR parameters to filter the frames. |
Defines if INCA checks or ignores the specified VLAN IDs.
Ignored | Packets pass the packet capture filter even if the property does not match. This is the default value. |
Checked | Packets are checked and filtered. INCA uses the AUTOSAR parameters to filter the frames. |
Defines if INCA checks or ignores the specified IP addresses (IPv4 and IPv6).
Ignored | Packets pass the packet capture filter even if the property does not match. This is the default value. |
Checked | Packets are checked and filtered. INCA uses the AUTOSAR parameters to filter the frames. |
Defines if INCA checks or ignores the specified ports.
Ignored | Packets pass the packet capture filter even if the property does not match. This is the default value. |
Checked | Packets are checked and filtered. INCA uses the AUTOSAR parameters to filter the frames. |
See also
Module Parameter for Ethernet (ETH) Interface
Working in the Hardware Configuration Editor