User Options for Data Exchange: LAB
To open this dialog box, click the User
Options
button and select the Data
Exchange tab. On the Data Exchange tab,
double-click in the Value field of the LAB option.
For the data exchange format LAB, you can make the following settings:
Write semicolons
Determines how INCA writes semicolons into the LAB file.
Write all defined semicolons
INCA writes all defined semicolons into the LAB file exports.
Write only needed semicolons
INCA writes only necessary semicolons into the LAB file exports.
EXAMPLE
LAB V1.3 entry template LabelName;Raster;DisplayMode;ExpOrder;Device;Comments
Option Write only needed semicolons:
aLabel;aRaster
Option Write all defined semicolons:
aLabel;aRaster;;;;LAB file version for CDM
Determines the default LAB file version when you write a LAB file from the Calibration Data Manager.
LAB file version for INCA
Determines the default LAB file version when you write a LAB file from the Experiment Environment and the Variable Selection Dialog.