Setting up a Table Stimulation Mode
The table mode uses a table as stimulus.
- Open the Stimulus window for a data generator channel (see Setting up a Channel in the Data Generator).
- In the Mode combo box, select table.
Click the Edit Table button to edit the table used as stimulus.
The table editor for one-dimensional tables opens.
In the table editor, do one of the following:
- Enter the desired values directly.
- Open the Edit menu and select File In Data to load an existing table.
Details about working with the table editor are described in Table Editor (Editor for Combined Types) and Working with Calibration Windows.
In the Time Scale field, enter a factor for the time scale.
The X axis values of the table are divided by this factor, and the results are used as time steps (in seconds) for stimulation.
- Click OK to accept the settings.
Note |
|---|
The table is processed only once. If you want to use it a second time to stimulate a channel, you have to restart the experiment. |
See also
Setting up a Channel in the Data Generator