Accumulated Deviation from Signal-based Value Range

Evaluates the values of an array of input signals with signal-based lower and upper limits and identifies exceedance situations.

Input(s)

Name

Description

Type

inputArray

Array signal including an arbitrary number of input signals

Array Signal

lowerLimit

Lower limit of range

Analog Signal

upperLimit

Upper limit of range

Analog Signal

Output(s)

Name

Description

Type

upperExcdBoolArray

Array indicating if upper exceedance occurred since the beginning of the measurement (bool)

Array Signal

lowerExcdBoolArray

Array indicating if lower exceedance occurred since the beginning of the measurement (bool)

Array Signal

upperExcdTimeArray

Durations of upper exceedances

Array Signal

upperExcdAccArray

Integrated values of upper exceedances

Array Signal

upperExcdSquareArray

Integrated square values of upper exceedances

Array Signal

lowerExcdTimeArray

Durations of lower exceedances

Array Signal

lowerExcdAccArray

Integrated values of lower exceedances

Array Signal

lowerExcdSquareArray

Integrated square values of lower exceedances

Array Signal

upperExcdCount

Count of signals with upper exceedance

Analog Signal

lowerExcdCount

Count of signals with lower exceedance

Analog Signal

maxUpperExcd

Maximum upper exceedance

Analog Signal

maxLowerExcd

Maximum lower exceedance

Analog Signal

maxIDUpperExcd

ID of signal with maximum upper exceedance (0-based)

Analog Signal

maxIDLowerExcd

ID of signal with maximum lower exceedance (0-based)

Analog Signal

totalUpperExcd

Total upper exceedance

Analog Signal

totalLowerExcd

Total lower exceedance

Analog Signal