Merging Contents of Dataset and ECU Memory

If the dataset contains both valid and invalid calibrations, it is not possible to download the complete dataset to the ECU memory as it is.

You have the following options:

To merge the contents of the dataset and the ECU memory:

  1. In the Devices field, select the devices for which you want to perform the selected action.

  2. In the Action field, activate Equalize.

    The From field shows the entry Datasets.

    The To field shows the entry Working page.

    The Apply to field shows the entry All calibrations.

  3. Check the Calibration access box.
  4. If necessary, activate or deactivate the ECU group via the Device group active field.
  5. Check the settings from the visual display of the selected action:

    The source is underlaid blue, the destination is underlaid orange.

  6. Click Do It.

    All valid calibrations are downloaded from the dataset to the ECU memory. Afterwards, the calibrations that are unknown in the dataset are uploaded from the ECU memory to the dataset. As a result, all calibrations are valid, and the data in both dataset and ECU memory are equal.

See also

Writing to ECU Memory

Reading ECU Memory