Uploading a Configuration File for VX Devices

  1. Open the INCA User Options .

  2. On the Hardware tab, click in the value field of the Vector VX config tool location option.

  3. Select the Vector VX configuration file (*.ini).

  4. In the Hardware Configuration Editor , add a VX device or select an already added device.

  5. On the 2 Parameters tab make the following settings:

    • Serial number: To add a serial number enter the serial number or click .

    • Project: Assign a project (database object) to the device.

  6. Click Configure.

    The Configure dialog box opens.

  7. Click Write to VX.

    The device is now configured with a new parameter set.

See also

Adding a Device

Searching for Hardware

Arranging Devices in the Hardware Devices List

Transferring Parameter Values

Grouping Control Devices

Removing a Device

Initializing Hardware