Settings for YT oscilloscope (outdated)
In the Experiment pane of the Display Configuration tab, properties for the elements used in the Experiment are displayed.
If you click on an YT-Oscilloscope (outdated) in the experiment structure, the corresponding properties are displayed in the following tables:
This table contains the following properties:
Name
Shows the name of the YT-Oscilloscope.
Background color
Opens a color palette. The set color is used as background color of the YT-Oscilloscope.
Channel color list
Defines the order of colors used for the channels.
Extent of time axis
Enables input of the length of the time axis in seconds.
Display mode
Defines behavior of measurement signal display after the maximum number of measure points is reached.
Oscilloscope | The display is point by point. If the maximum number of points is reached, the display window is cleared and the display begins again. | ||
Recorder | The display is point by point. If the maximum number of points is reached, the oldest points are deleted. | ||
Curtain | The display is point by point. If the maximum number of points is reached, the measuring signal is continuously overwritten.
|
Grid type
Defines the grid of the signal view.
No grid | No grid is shown. |
Dynamic grid | The grid size depends on the scaling of the signal. |
Fixed, linear grid | The grid size is fixed. |
Grid division
Defines how the grid is divisioned.
Show legend
Defines whether a list of channels is to be displayed.
Show axes ranges
Also displays the axis ranges for each signal in the signal list.
Show rate
Defines whether the measurement variables grid is to be displayed.
Show numeric values
Defines whether the numeric value of each signal is displayed in the measure value list.
Current Value | Display the current measured value. |
No | No numeric display of the measured value. |
Minimum Peak | Display the smallest measured value. |
Maximum Peak | Display the largest measured value. |
Region of shown numeric values
Defines the display of number values.
At column: Name | The values are displayed in the same column as the name. |
At own column | The values are displayed in a separate column. |
Highlight selected channels in graphic
Defines whether the selected channel is to be highlighted on the graphic display.
Rotation of each axis description
Defines the angle of the axis label.
This table contains the following properties:
Name
Shows the names of the measure variables contained in the YT-Oscilloscope.
Data representation
Displays the type of information representation.
Phys | Represents the value of the measure variable as physical variable. |
Hex | Represents the value of the measure variable as hexadecimal variable. |
Dec | Represents the value of the measure variable as decimal variable. |
Bin | Represents the value of the measure variable as binary variable. |
Line style
Defines the type in which the line of a measurement curve should be displayed.
Color
Opens a color palette. The set color is used as line color of the measure variable.
Display type
Defines the way in which the points on a measurement curve are connected in the graphic display.
Lines | The measured values are interconnected by a continuous line. |
x | The Y-value change from measured value to measured value; the curve is stepped. |
Line width
Defines the line width of the measure variable.
Symbol
Defines the default form of the symbol at the acquisition points: you can select between a rectangle, a cross, a circle and a triangle.
Symbol size
Defines the size of the symbol at the acquisition points (between 5 and 100).
Fill style
Defines whether the signal areas are to be highlighted color for digital signals.
None | The digital signal is displayed as a line. |
filled | The area between the signal and the x axis is filled with the corresponding signal color. |
Show index
Defines whether the signals in the graphic region of the oscilloscope are to be index by default with the signal number from the tabular signal list. Display of the index number can be activated separately for the display in INCA and the printout.
No | Signals are not indexed in the graphic region of the oscilloscope. |
View | The graphic signals are indexed in the graphic region of the oscilloscope in INCA, but not in the print-out. |
Printout | The graphic signals are indexed in the print-out, but not in the graphic region of the oscilloscope in INCA. |
View and Printout | The graphic signals are indexed both in the graphic region of the oscilloscope in INCA and in the print-out. |
Axis
Defines the Y-axis of the YT-Oscilloscope.
Axis range
Defines the axis range of the measure variable.
Device