Interface specifications
Automotive Ethernet Interface
|
Item |
Characteristics |
|
Connection |
Automotive Ethernet 1000 Base-T1 |
|
Protocol |
XCP on TCP/IP or UDP/IP |
|
IP address |
Dynamic (standard, for INCA) or Static (e.g. for Rapid Prototyping) by using the M-ETK Configuration Tool (default IP address: 192.168.40.14) |
|
Cable length |
max. 8 m |
|
Ethernet Interface |
DC decoupling Max. Isolation Voltage 60 V DC, according IEC 61010-1 ("Limit values for accessible parts" in normal, dry condition) |
|
Note |
|---|
|
The Automotive Ethernet interface is not compatible with the standard Ethernet interface of ETAS modules. A 1000 Base-T1 Automotive Ethernet Media Converter is needed to connect the M-ETK + M-ETK-AB1.0 to the PC. |