Interface specifications

Automotive Ethernet Interface

Item

Characteristics

Connection

Automotive Ethernet 1000 Base-T1

Protocol

XCP on TCP/IP or UDP/IP

IP address

Dynamic (standard, for INCA) or

Static (e.g. for Rapid Prototyping) by using the M-ETK Configuration Tool (default IP address: 192.168.40.14)

Cable length

max. 8 m

Ethernet Interface

DC decoupling

Max. Isolation Voltage 60 V DC, according IEC 61010-1 ("Limit values for accessible parts" in normal, dry condition)

Note  

The Automotive Ethernet interface is not compatible with the standard Ethernet interface of ETAS modules. A 1000 Base-T1 Automotive Ethernet Media Converter is needed to connect the M-ETK + M-ETK-AB1.0 to the PC.