Basic operation

Adapterboard Connection
  • Align the M-ETK Adapterboard variant with the designated connector on the M-ETK-T Device.

  • Gently push until it is securely seated.

Physical Integration into ECU

The M-ETK is desig ned for on-premise integration. This typically involves connecting the M-ETK Device and its Adapter board to the development ECU's hardware interfaces. Please consider, that the M-ETK has to be mounted in the area of low voltage of the ECU.

Power Connection

Connect the M-ETK to the ECU's low voltage power supply or a suitable external power source according to its specified voltage requirements.

Software Integration

The required M-ETK software components (e.g., Distab, 2-page calibration handling, handshake mechanisms) need to be integrated into the ECU's software. This is typically performed by a HW/SW Integrator.

Network Connection

Connect the M-ETK's Automotive Ethernet XCP interface to your development network.

Feature License Activation

Activate any purchased feature licenses (e.g., Trace2Pin) through the provided software tools.