Hardware specifications

Ambient conditions

Operating temperature range

-40°C to +70°C
-40°F to +158°F

Storage temperature range
(without packaging)

-40°C to +85°C
-40°F to +185°F

Max. relative humidity
(non-condensing)

85% (operation)

95% (storage)

Max. altitude

5000 m / 16400 ft.

Degree of contamination
(IEC 60664-1, IEC 61010-1)

2

Protection rating (IEC 60529)
(when closed)

IP40

Electrical data

Operating voltage range

7 V to 29 V DC

Max. current consumption

14 A

Typical current consumption (operation) 1)

approx. 210 mA (at 14.4 V DC)

Typical current consumption (standby) 1)

approx. 60 mA (at 14.4 V DC)

Maximum voltage to ground or to all accessible
parts (e.g. ECU housing, vehicle chassis)

50 V DC / 30 V AC

Overvoltage category
(mains supply, IEC 60664-1)

II

Power supply of connected modules

Each "ETH" connection: nom. max. 2 A

Energy management

On/Off with Start/Stop of Ethernet data transfer (On/Off upstream module)

Protection

Reverse polarity-protected and load dump protection in accordance with ISO 16750-2 Test B (central load dump protection required)

1)without power supply of connected modules

Mechanical data

Dimensions (H x W x D)

36 x 127 x 160 mm
1.42 x 5.00 x 6.30 in

Weight

0.64 kg / 1.42 lb