Status indicator

The ES600.2 is equipped with LEDs for displaying the module's operating state, as well as for displaying the function of the Automotive Ethernet interfaces.

Note  

When the ES600.2 is switched on, all LEDs light up briefly.

ON

LED code

Display

State

Off

No power supply

Flashing green

Module in operating mode "Standby", minimum current consumption. Changing to the "Normal" state requires a Wake-Up event

Lit green

Module in operating mode "Normal"

Flashing green

Module is synchronization master, module is not externally synchronized

Flashing green

Module is synchronization slave, module is externally synchronized: at FE-HOST connection

Flashing red

Firmware update is being performed

Lit red

Error

TX (FE-HOST)

LED code

Display

State

Off

No Ethernet connection

Green

Ethernet connection (upstream) active

Flashing green (3 times per second)

Data transfer with 10 Mbit/s

Flashing green (6 times per second)

Data transfer with 100 Mbit/s

TX (GE-HOST)

LED code

Display

State

Off

No Ethernet connection

Green

Ethernet connection (upstream) active

Flashing green (3 times per second)

Data transfer with 10 Mbit/s

Flashing green (6 times per second)

Data transfer with 100 Mbit/s

Flashing green (12 times per second)

Data transfer with 1000 Mbit/s

TX/ER1 - 6 (ETH)

LED code

Display

State

Off

No Ethernet connection

Green

Ethernet connection (downstream) active

Flashing green (3 times per second)

Data transfer with 10 Mbit/s

Flashing green (6 times per second)

Data transfer with 100 Mbit/s

Lit red

Current overload by the connected module