Electrical connection
Electrical Safety and Power Supply
-
Only connect the product to electric circuits with safety extra-low voltage in accordance with IEC 61140 (devices of class III) within the voltage limits for accessible parts as per IEC 61010-1.
-
Observe the connection and setting values.
-
The power supply for the product must be safely disconnected from the supply voltage. For example, use a car battery or a suitable lab power supply.
-
Only use lab power supplies with dual protection for the supply network (with double/reinforced insulation (DI/RI)).
-
The power supply must be suitable for use according to the ambient conditions for the product.
-
It is possible to discharge the vehicle battery in regular operation and long standby operation.
-
Central load-dump protection is required for operation.
Connection to the Power Supply
The product is powered via an ETAS module in the test setup.
To de-energize the Product
- Disconnect the product from the power supply in one of the following ways:
-
Switch off the laboratory power supply for the test setup.
-
Disconnect the test setup's connection to the vehicle battery.
-
Disconnect the product from the ETAS module supplying the power.
-
Disconnect the product from all interfaces.