Interface specifications

LIN interface

LIN

Two interfaces, isolated from the host connector

Standard

Compliant to LIN 2.0, LIN 2.1, LIN 2.2, LIN 2.2 A, and ISO/DIS 17987-4.2

Controller

LIN core (FPGA)

Transceiver (physical layer)

TLIN1029

LIN reference voltage VBAT

12 V LIN systems: VBAT internal from the module or external from the LIN bus,can be selected in the application software 1)

Operating modes

24 V LIN systems: Only VBAT external from the LIN bus

Clients and operating modes

Master or slave, can be selected in the application software 2)

Clients per LIN channel

Max. 4

Clients and LIN standard

Client 1: Master or slave
Client 2 - 4: Slave

Client 2 - 4: Compatible with the LIN standard used by Client 1

Electrical isolation

Interface separated from the other interfaces

1): Selection of internal LIN VBAT by INCA currently in preparation
2): Support for master operating mode by INCA currently in preparation

Note  

Multi-client simulation scenarios:
Turn on the LIN bus and configure all slave applications and PID responses before starting LIN communication.