Add files
-
In the Sources step, click
.
-
In the file selection dialog, select the measurement files you want to add to the job.
The validity of MF4 files is automatically checked upon adding. The Valid column displays a green check mark for valid files and a red cross for corrupt ones.
If a corrupt MF4 file is detected, you can enable the Best-effort repair of structural issues in MDF files checkbox to attempt a best-effort repair. Unreadable sections may be removed during the repair, so it is recommended to work on a copy of the original file.
-
Click Open.
The selected files are added to the job.
-
Use the Signal source checkbox to enable or disable individual files for signal selection.
By default, the first five added files are activated as signal sources.
-
To remove a file, click
.
-
To remove all added files and folders, click
.
BLF files
If BLF files are added, a signal definition file is required to interpret the CAN data.
-
To select a signal definition file, click
.
-
In the file selection dialog, select a DBC or ARXML file.
-
If a DBC file is selected, enter an integer value in the CAN bus ID input field.
-
If an ARXML file is selected:
-
In the CAN bus ID input field, enter an integer value.
-
From the Bus name drop-down list, select a bus.
-
-
The configuration is applied to all added BLF files.