Input Configuration

When you create a new ASCMO-STATIC ExpeDes project, several inputs are created automatically. These must be named and configured accordingly, and additional inputs may also be required.

Defining a new input

  • Click Add to define a new input.

    A new input is added to the end of the list.

    If you select a specific input (by clicking the row number) before you click Add, the new input is inserted directly under the selected row.

  • To duplicate existing inputs, select one or more inputs and click Clone.

    The duplicates, named <input_name>_2, are added below the respective originals.

Configuring an input

To configure an input, proceed as follows.

  • Click in a cell.

    The cell becomes an input field.

  • Enter the desired value, then press <Return>.

    You can specify the following parameters.

    Input Name: name of the input quantity to be measured

    Minimum / Maximum: lower/upper limit of the measurement range for the respective input

    Note  

    Input names must be unique.

  • Use the h and i buttons to move an input to another position in the list.

Importing names of inputs

  • Use the Import button to import a list of names available in one of the following file formats:

    • Lab File (*.lab), e.g ETAS INCA Variable File
    • MS Excel (*.xls, *.xlsx)
    • Comma separated values (*.csv)
    • Configuration File (*.ini), e.g. ETAS ASCMO Channel Config File
  • A window opens from which you can select the names file to be imported.

Removing an input

  • Select the row and click Delete.