"Export Optimization Problem to MOCA" Window (ASCMO-DYNAMIC)

The "Export Optimization Problem to MOCA" window is opened via Optimization Export to MOCA in the ASCMO-DYNAMIC window.

This window contains the following elements:

"Choose a File Path and Name" area
  • "File Name" field and button

    Enter or select (via the button) path and name of the resulting ASCMO-MOCA project file.

    If you do not enter a path, the ASCMO-MOCA project file is stored in the same directory as your ASCMO-DYNAMIC project.

  • Open MOCA after Creation option

    If activated, the new project file is opened in ASCMO-MOCA.

  • Export as Plant Model option

    If activated, the outputs are created as functions of all inputs in the ASCMO-MOCA project. None of the inputs is created as parameter.

"Specify OP axes" area

Note  

Invisible if Export as Plant Model is activated.

In this area, you can select up to four operating point axes from the inputs , which are the inputs to the created maps in ASCMO-MOCA.

  • "<n>. OP" combo box

    Use the combo box to select an input channel as <n>th operating point axis.

"Specify dependency of non OP axes" area

Note  

Invisible if Export as Plant Model is activated.

In this area, you can define the way the normal inputs depend on the operating point axes.

  • "<input>" field

    Use the combo box to specify the input's dependency on the operating point axes. Available selections:

    Curve(<op axis i>)

    one curve for each operating point axis

    Map(<op axis i>, <op axis j>)

    one map for each combination of two operating point axes (up to 6 maps)

    Cube3d(<op axis i>, <op axis j>, <op axis k>)

    one 3D cube for each combination of three operating point axes (up to 4 cubes)

    Note  

    Only available if three operating point axes have been selected.

    Cube4d(<op axis i>, <op axis j>, <op axis k>, <op axis l>)

    one 4D cube that depends on all operating point axes

    Note  

    Only available if four operating point axes have been selected.

  • use for all next to the first "<input>" field

    If you click on this button, the selection of the first normal input is selected for all normal inputs.

OK

Closes the window and starts the export.

Cancel

Closes the window without starting the export.

See also

Optimization (ASCMO-DYNAMIC)

Optimization Menu - Export to MOCA