Changing the Visibility of Individual Sequence Calls

Note

This topic applies only to SWCs specified as block diagrams.

To change the visibility of individual sequence calls, block-local sequence calls or connectors, proceed as follows.

Hiding a Sequence Call:

Note

Connectors cannot be hidden.

  1. Do one of the following:

    • Right-click the input port of the element to which the sequence call is linked, then deactivate the Sequence Call command in the context menu.
    • Right-click the sequence call and select Hide from the context menu.

    The sequence call is hidden.

Showing a Sequence Call:

  1. Do one of the following:

    • Right-click the input port of the element to which the sequence call is linked, then activate the Sequence Call command in the context menu.
    • Right-click the element to which the sequence call is linked and select Show Sequence Calls in the context menu.

    The sequence call is displayed.

Highlighting a Port:

  1. Right-click a sequence call or connector.
  2. In the context menu, select Select Complete Port to mark the port to which the sequence call/connector is linked.

    The input port of the relevant diagram element is shown in blue. This feature is useful in order to follow sequence calls in complex diagrams.

See also

Sequence Calls

Block-Local Sequence Calls