Implementation for: / Window

This window contains the following functions:

Overflow Handling field

Displays the way an overflow is handled.

The Allow zero in phys. interval option could be activated when the generated code should not test for division by zero, even though the denominator interval includes zero. Therefore, option is an assurance to the code generator that the user himself will take care that the denominator does not assume the value zero.

Note

Wrong usage of this option can lead to severe exception errors in the control unit.

Pre-shift:

Indicates if the numerator should be maximized automatically by left shift to improve numerical accuracy. The following settings can occur: