Error Messages: MB* – ML*

The list of ASCET error messages is split in several parts.

Part 4: MB* – ML*

Message code

Error message

See also

MBdl7

unbalanced number of start/stop atomic in <%1>

Unbalanced Number

MBdl71

atomic sequence must begin with start atomic in <%1>

Creating a Sequence of protected Sequence Calls

MCCg1

Assignment to a complex variable <%1> is not allowed for controller target

MCCg11

Assignment to a complex variable <%1> is not allowed, if "asReference" is not specified

MCCg3

%2 <%1>: %3 not supported for controller targets

MCg11

identifier <%1> already declared – used as keyword

MCg2

identifier <%1> not declared

MCg21

class <%1> not declared

MCg22

method <%1> not declared

MCg3

identifier <%1> already declared in scope <%2>

MCg4

identifier <%1> not declared in scope <%2>

MCg5

type mismatch between <%1> and <%2>

MCg6

type mismatch: expected <%1>, got <%2>

Type Mismatch

MCg61

type mismatch: expected <log> got <%1>

MCg62

type mismatch: expected scalar type, got <%1>

MCg7

wrong number of arguments for call of <%1>

MCg8

macro on stack is not an expr

MCg81

macro on stack is an expr

MCta33

%1 access to %2 <%3> in method <%4> denied

MCta40

reuse of derivative <%1> in argument not allowed

MCta45

derivative call can only be used with states

MCta50

put direct link statement into <directOutputs> method

MCta51

put nondirect link statement into <nondirectOutputs> method

MCta52

output <%1> is assigned direct and nondirect

MCta60

missing declaration of variable <%1> in element's list

MCta66

do not call function <%1> in method <%2>

MIa1

Cannot generate fixed point code for the non-linear formula <%1> of <%2>

Fixed-Point Code for Non-Linear Formula

MIa10

assignment: invalid specification (<Limit Assignment : TRUE>) at element "%1", due to usage as running variable in FOR stmnt

MIa11

overflow detection: invalid specification (<%1> and <%2>) at element "%3", due to %4

MIa12

limited assignment of value %1 to <%2> is out of implementation interval %3

MIa13

limited assignment of <%1> to <%2> not possible without overflow limitation due to value range of <%3> exceeding maximum bit length of target

MIa14

limited assignment of <%1> to interval <%2> not possible without overflow limitation due to value range of <%3> exceeding maximum bit length of target

MIa15

Cannot assign <%2> to INOUT parameter <%1> because of different implementations

MIa2

Implementation interval %1 of <%2> too large for implementation type

Integer Interval too Large

MIa21

Modulus must be greater than 1, but is %1

MIa22

Element of type %1 cannot have unit %2 with scale or offset

MIa23

Element <%1> %2 cannot have generic unit %3

MIa3

Physical interval %1 of divisor contains zero.

MIa4

Implementation type of <%1> is too large.

MIa5

Cannot mix floating point and fixed point values.

MIa50

Rescalable element <%1> must be of type cont, but is of type %2

Elements with Rescalable Implementstion

MIa501

%1 element <%2> must not have a rescalable %3

MIa51

Rescalable element <%1> must have local scope, but is %2

MIa52

Rescalable element <%1> must have a linear formula with zero offset, but formula is %2

MIa53

Rescalable element <%1> must have an integer implementation type, but the implementation is %2

MIa54

Rescalable element <%1> must have master set to implementation, but is set to model

MIa55

Element %1 cannot be rescalable due to %2

MIa6

Cannot assign %1 reference from <%3> to <%2> because of different implementations

MIa61

Cannot determine implementation of method local variable %1, because the right hand side does not have an implementation

MIa7

Expander <%1> does not support float type of <%2>

MIa8

Implementation interval of <%1> is empty.

MIa9

scale must be non negative

MIle1

<%1> is not a valid ANSIC identifier

MIle100

Duplicate C-Code name "%1" for component types – either change name or associated naming template

MIle101

Duplicate C-Code name "%1" for exported elements – either change name or associated naming template

MIle11

A BDE-Case operator is not allowed in the condition of a while loop

MIle111

"%1" is not a valid ANSIC identifier – %2

MIle12

"%1" is not a valid ANSIC identifier --- check template "%2"

MIle13

An explicit read or write with status handler is not allowed in the condition of a while loop

MIle150

Too many %1 (%2) -- simulation data structures support only up to 65535 elements -- maybe problem is due to big arrays/matrices of record

Arrays and Matrices of Record Type – Special Features

MIle2

use of reserved name <%1> --- please change it

Reserved Keywords

MIle20

Arithmetic service <%1> required but not defined

Arithmetic Services

Complement Services for Redundant Data Storage

MIle201

Round service <%1> required but not defined

MIle202

Invalid round service description <%1> found – %2

MIle21

Interpolation service <%1> required but not defined

MIle22

Multiple complement services for type "%1" defined in file "%2"

Complement Services for Redundant Data Storage

MIle23

%1 types can not be used as %2 data types, see "%3" in file "%4"

MIle24

Unknown type used as redundant data type, see "%1" in file "%2"

MIle25

Empty service definition for "%1" in file "%2"

MIle26

Only %1 types can be used as %2 data types, see "%3" in file "%4"

MIle27

Invalid number of arguments (%1) for optional service "%2", see "%3" in file "%4"

MIle3

invalid template <%1> for key %2 --- unknown argument %%%3%%

MIle301

invalid template <%1> for key %2 --- odd number of "%%" or "?" symbols

MIle302

Template for message access macro contains %1, but %2

MIle33

invalid template <%1> for key %2 --- odd number of "%%" or "?" symbols

MIle4

interval %1 does not fit in a valid integer type, with respect to option "maximum bit length"

MIle41

Limitation is missing on assignment

MIle5

Using message "%1" in method "%2" with code generation option messageUsageVariant=NON_OPT_COPY is not supported

MIle51

Internal Access (%1) of "%2" differs from internal access (%3) of "%4". Note: actual access will be analyzed by ASCET - please change specification

MIle533

%1 access to data element "%2" not expected (according to imported ARXML info), but found in runnable "%3"

Software Component Development

Usage Information from Imported ARXML Files

MIle5331

%1 access to data element "%2" not expected (due to missing imported ARXML info), but found in runnable "%3"

MIle534

%1 call to operation "%2" not expected (according to imported ARXML info), but found in runnable "%3"

MIle5341

%1 call to operation "%2" not expected (due to missing imported ARXML info), but found in runnable "%3"

MIle535

could not parse ARXML info usage condition: "%1"

MIle58

Status operator to access element "%1" is not supported - %2

MIle60

not supported type combination for oneDInterpolation: expected cont/cont (float/float) or disc/disc (int/int) respectively

MIle61

not supported type combination for twoDInterpolation: expected cont/cont/cont (float/float/float) or disc/disc/disc (int/int/int) respectively

MIle62

Local distribution "%1" with a user-defined type for the search result is not supported for the generation of multi-instance software components.

MIle7

wrong OS specification with respect to <numHWLevels> entry in target.ini (specified <%1>, calculated <%2>)

MIle76

Interval of assert operator %1 and operand interval %2 have no common values

Assert Operator

MIle77

index <%1> out of bounds for indexed expression "%2"

MIle8

invalid compile time constant expression – floating point constant detected

MIle801

invalid compile time constant expression – mix of signed and unsigned operands with signed result

MIle802

invalid compile time constant expression – usage of %1 value for a system constant with type %2

MIle810

The following %2 diagnostic code "%1" is missing in this ECU-SW

MIle811

Diagnostic code "%1" has wrong type ("%2") – Please use scalar type

MIle812

Diagnostic code "%1" must not be mapped to ECU label

MIle9

division by zero detected

MIle91

implementation interval %1 of denominator represents zero

MIle92

Cannot convert an expression the negative values %1 to a modular type

MIle93

F-Division is not supported for operand %1 of type %2

MIle94

Cannot choose a limit interval for floating point expressions

MIle95

Cannot convert an expression that may be 0 to a reciprocal type

MIle9993

Casting leads to overflow on %1 bits targets

MLm10

need %3 imported element <%1> with type <%2>

MLm11

missing component type for <%1>

MLm12

missing name for implementation type of element "%1"

Implementation Types

MLm14

implementation type "%1" of element "%2" undefined in current project

MLm15

Invalid specification for "Limit to maximum bit length" at element <%1>

MLm2

multiple export of <%1>

MLm20

both export <%1> and import <%2> must be of kind <%3>, but import is of type <%4>

Element Configuration

MLm21

both export <%1> and import <%2> must have identical %3

MLm22

multiple export of "%1"

MLm23

multiple mapping of "%1" %2 all of (%3) --- %4

Accessing ASCET Messages

Accessing Calibration Parameters

ASCET‑SE EHOOKS Target User Guide

MLm3

<%1>: data types other than real are currently not supported

MLm302

<%1> – due to %2 – can not be used as reference

MLm31

Element <%1> has invalid physical/implementation interval for specified formula

MLm32

Element <%1> has moebius formula and implementation with critical value <%2> as border of implementation interval <%3> -- please change implementation interval

MLm4

missing %1-distribution for group char table <%2> --- possibly deleted

MLm41

missing %1-distribution for group char table <%2>

MLm42

expected %1-distribution for group char table <%2> to be exported

MLm43

Distribution %1 without group char table

MLm44

Inconsistent interpolation on group char tables for distribution %1

MLm45

Incompatible monotony of interpolation on group char tables for distribution %1

MLm50

could not find file <%1>

MLm60

actual dependent parameter missing for formal parameter <%1> of element <%2>

Dependent Parameters

MLm61

dependent parameter formula missing for element <%1>

Creating the Formula for Dependent Parameters

MLm70

imported type <%1> and exported type <%2> different for element <%3>

MLm80

must not start model element "%1" with ASCET namespace prefix "%2"

MLm81

method name "builtInStateReset" not allowed in state machines

MLm90

formula named "%1" used for item <%2> not known in current project --- please create formula; hint: use "Global Formulas – Add missing" menu

Adding Missing Formulas

MLm901

rescaling formula named "%1" used for item <%2> must be linear

Components with Rescalable Elements

MLm902

rescaling formula named "%1" used for item <%2> must have a zero offset

MLm903

rescaling formula named "%1" used for item <%2> must have a positive scale

MLm91

formula name used for item <%1> is empty --- please specify valid formula name

Editing a Formula

MLm92

formula named "%1" does not comply with ASAM-2MC --- please rename formula; hint: use "Extras – Global Replace Formula" menu

Replacing a Formula Recursively

back to top

See also

List of Information Messages

List of Warning Messages