Error Messages: E*
The list of ASCET error messages is split in several parts.
|
Part 1: E*
Message code | Error message | See also |
|---|---|---|
ECCg0 | %1 | |
ECCg10 | Characteristic table/distribution must be parameter <%1> | |
ECCg11 | Separate "search"/"interpolate" functions of characteristic tables are not supported. Please use "getAt" function instead. | |
ECCg12 | Distribution of fixed characteristic <%1> must be regular. | |
ECCg13 | Bit types are not supported for instance variables of classes: <%1> | |
ECCg41 | Memory class <%1> specified for %2 is not declared in file "memorySections.xml" – Please add declaration | ASCET‑SE User Guide, |
ECCg9 | (CodeGenerator) Element <%1>: size of values (%2) exceed size of type (%3) | |
ECg1 | logic has semantic errors; should not be able to generate Code | |
ECg2 | Invalid %1 path name: %2 | |
ECg5 | %1 "%2", used as SHORT-NAME tag in AUTOSAR XML generation, must not %3 | |
ECg84 | Invalid template parameter(s) "%1" used for symbol "%2" | |
ECg85 | "%1" is not a valid ANSIC identifier --- check symbol template "%2" | |
EIa1 | Code Generation (internal) – %2 | |
EIa2 | Code Generation – %2. Try smaller intervals or larger quantizations | |
EIa21 | dT implementation not representable – Try larger interval or smaller quantization (e.g. 0.001) | |
EIa3 | Interval %1 does not fit in a valid integer type, with respect to option "maximum bit length" | |
EMake0 | %1 | |
EMake10 | Cannot generate code because of a cyclic dependency of components in sub graph %1 | |
EMake20 | Component name "%1" is not unique in project "%2" | |
EMake21 | Class %1 has parameters, so all instances must have the same data set | |
EMake22 | Interpolation scheme must be the same in all instances of "%1" for element named "%2" | |
EMake220 | %3 %1 (original value %2) not found for interpolation %4 | |
EMake221 | %1 is empty for interpolation %2 | |
EMake222 | Invalid interpolation mapping because of flag "%1" | |
EMake223 | Alias interpolation "%1" is not mapped | |
EMake224 | Interpolation %1 must allow increasing or decreasing axis points | |
EMake23 | Cannot use experimental expander for controller code generation | |
EMake24 | Object Based Controller Implementation can only be used together with an ASCET‑SE target | |
EMake241 | Special implementation "Mixed_Physical_Implementation" for element "%1" can only be used together with physical code generation – please select another implementation | |
EMake25 | Cannot use experimental code generation with controller target | |
EMake26 | Generation of operating system configuration is required using experimental targets – please activate appropriate Build option | |
EMake27 | Cannot create exported element "%2" due to multiple implementations of component "%1" | |
EMake28 | maximum size of %1 defined in tool options has invalid value <%2>. Allowed range is <%3>. | |
EMake30 | Names of datasets (%1) used in current project are not unique for component "%2" | |
EMake31 | Dataset and implementation must be identical for all instances of Module "%1" | |
EMake32 | Missing implementation set for component "%1 | |
EMake33 | Missing %1 set for element "%2" in component "%3" | |
EMake34 | Inconsistent use of %1s in model: %2>>%3 vs. %2>>%4 | |
EMake41 | Module "%1" should be instantiated only once, due to single instance semantics | |
EMake42 | Only one %1 can be used in an ASCET project | |
EMake43 | AUTOSAR use case requires one instance of a %1 to be used in an ASCET project | |
EMake44 | Cannot use "%1" code generation for AUTOSAR use case | |
EMake50 | Multiple defined conversion name "%1" – used as formula as well as enumeration name | |
EMake51 | "%1" instances can only be used in %2 components | |
EMake52 | Instances of %1 components must not be used in %2 components | |
EMake60 | Target type "%1" not unique, used in multiple declaration files: %2 | |
EMake61 | Memory segment ID "%1" not unique, used in multiple declarations | ASCET‑SE User Guide, |
EMake610 | Target %1 does not support %2 – please change option or target | |
EMake611 | Unsupported value "%3" for target %1 related option "%2" – please change option | |
EMake62 | Memory segment ID "%1" is reserved for internal use | ASCET‑SE User Guide, |
EMake63 | Memory segment ID "%1" contains invalid characters | |
EMake64 | Memory segment priority "%1" is not unique | |
EMake65 | Unknown Memory segment ID "%1" used to define a default memory class | |
EMake66 | Memory segment label "%1" not unique | |
EMake67 | Unreadable read costs for memory section <%1> -- see memorySections.xml in your target directory | ASCET‑SE User Guide, |
EMake68 | Schema Validation Error for memory section <%1> -- see memorySections.xml in your target directory | |
EMake70 | Invalid OS specification – task list must not be empty | |
EMake80 | Component prefix "%1" is no valid ANSI C identifier; see project options | |
EMake81 | Component name "%1" is no valid ANSI C identifier | |
EMake82 | AUTOSAR SW Component name "%1" is reserved within AUTOSAR tool chain – please change | |
EMake90 | Invalid template "%2" – %1 | |
EMake99 | Invalid %1 build tool configuration: %2 not supported – please change setting | |
EOS1 | no operating modes specified | |
EOS3 | illegal identifier <%1> for task – must be compliant with ANSI C | |
EOS4 | Operating system %1 is not supported for target %2 | |
EVal01 | general data model validator error: "%1". |
See also