Data Exchange Options
In the Data Exchange node, you set the options for data exchange. The exchange formats DCM V1.x and 2.x, and data exchange with INCA and ASCET from V4, are supported.
Data File Path
Directory of the generated data file.
Extension for Output File
File extension for data exchange file.
Possible values: dcf / dcm / kon
DCM Format version
Determines the DCM version to be used.
Possible values: DCM V1.x / DCM V2.x
Write Enums
Determines whether enumerations are written in TEXT format (only for DCM V1.x).
Write Sampling Points
Determines whether sampling points are written in DCM V2.x syntax (only for DCM V1.x).
Case Sensitive Names
Specifies whether upper/lower case are taken into account.
If the option is disabled, e.g., a parameter named CONT is mapped to a parameter named Cont during import.
Include Booleans
Specifies whether Booleans are taken into account.
Include Dependent Parameters
Specifies whether dependent parameters are taken into account.
Boolean format
Determines the format of Booleans (only for DCM V2.x).
Possible values: true/false / Integer
Show Log File for Load / Show Log File for Save
Specifies whether the log file for read/write processes is displayed.
Log File for Load / Log File for Save
Path and name of the log files for read and write processes.