Activating Cycle Time Monitoring

  1. Open a CT block.
  2. In the Extras menu, point to Default Project and select Open to open the default project for the CT block

    Or

  3. Open a hybrid project (see Projects and Hybrid Projects).
  4. Activate the OS tab of the project editor.

    In the Tasks pane, you find the tasks automatically defined for the CT block (see Combining Continuous Time Blocks With Modules).

  5. Select the simulate_CT1 or event_CT1 task.
  6. From the Pre-/post hooks combo box, select Monitoring.

    The monitoring variables for each task are generated during the next code generation for an experiment. You can show them in the measure windows or write them to the data logger (offline experiment only).

See also

Projects and Hybrid Projects

Combining Continuous Time Blocks With Modules